Servicing Connecticut, Western Massachusetts, and Hudson Valley, NY

Chase Durulite Standard Traffic Doors

This versatile door is capable of filling the needs of a wide variety of applications. From the daily rigors of forklift traffic, to refrigerated applications, to USDA and washdown applications. The strength of the Durulite industrial is due to its rotationally molded cross-linked polyethylene construction. Standard tests for impact resistance indicate that cross-linked polyethylene is five times more puncture-resistant and three times more flexible than ABS material. The corrosion resistant panel is ideal for washdown applications as it has no gaps or joint seams.

TKO Vertacool Cold Storage Dock Door

The Industry’s First Door Specifically Designed for Use with Vertical Storing Dock Levelers

Answering the demand for a cost-effective and energy-efficient dock door for use in Vertical Storing Dock Leveler applications, TKO created the VertiCool door. More effective than a standard sectional door and less expensive than a Vertical Rise Freezer Door, the VertiCool provides superior energy efficiency at a lower cost of ownership.

DESIGN BENEFITS

  • 4” thick closed cell XEPS foam panel provides R-23 for superior thermal protection
  • 48” high panels reduce the number of panel joints by 50% in comparison to industry-standard 24” high panels. Fewer panel joints ensure a better sealing door
  • Dual compression side seals are mounted to door panel and removed from impact zone when door is open, preventing seals from sustaining damage
BROCHURESPECIFICATIONS
  • Patent-pending, heavy-duty full opening height polymer thermal break track with 14 gauge galvanized steel guides
  • Polymer track wrapped with energy reflective foil fabric
  • Interior and Exterior panel skins to be constructed of .030” aluminum with an enamel finish
  • Dual overlapping header seal
  • Dual compression loop bottom seals
  • Unique heavy-duty fixed plunger reduces door maintenance
  • Available Wind Load option

Hercules Extreme Low Temp Overlap Freezer Door

  • Ideal door for blast freezer and extreme low temp applications
  • Appropriate in a wide variety of applications
  • Most often used as a pedestrian traffic door for extreme low temperature, blast freezers, or any controlled environment)

Hercules Bi-Parting Cooler & Freezer Door

  • Ideal for applications where fast opening and closing is important, especially in areas where material handling equipment such as forklifts and pallet jacks operate
  • Suitable for coolers, freezers, warehouses and industrial buildings
  • Available with electric or manual operation
BROCHURE
BROCHURE

Hercules Heavy Duty Vertical Sliding Door

  • Ideal for applications where there is minimum side room, or when several door openings are close together such as with warehouse loading docks
  • Suitable for drive-thru traffic in conjunction with forklifts and other freight transfer vehicles
  • Double vertical lift door is also available if head room is limited to slightly more than half the door height
  • Available with electric or manual operation

Hercules Horizontal Sliding

  • Ideal for applications where fast opening and closing is important, especially in areas where material handling equipment such as forklifts and pallet jacks operate
  • Suitable for coolers, freezers, warehouses and industrial buildings
  • Available with electric or manual operation
BROCHURE

Dynaco M2

CONTROL CIRCUIT
Electronic control board with 5V logic. Options included: B2, E2 wiring, timer to close, mid-stop, delay on reverse, maximum run timer.

OPERATOR
Manufactured by MANARAS: Opera-H-Jackshaft Operator with industrial duty motor for up to 25 cycles/hour or 100 cycles/day. Electronic control board supplied with floor level disconnect for manual operation.

DETECTORS
An infrared photocell, detecting the presence of a pedestrian or a vehicle, immediately opens the door and keeps it open as long as the presence is detected. Height of the photocell: 12” from the floor (optionally up to maximum 24” upon request).

A bottom edge detector opens the door when it hits an obstacle during the closing cycle. This detector is positioned in the bottom part of the curtain.

POWER SUPPLY
Standard: 115 VAC. Optional single phase 208-230 VAC, three phase 208 VAC, three phase 460 VAC, three phase 575 VAC.

Frequency: 60 Hz. Circuit protection to be provided by the customer: 8A for 115/1/60, 4A for 230/1/60, 2.1A for 208/3/60, 1A for 460/3/60, 0.8A for 575/3/60.

SPACE REQUIREMENTS
All indicated dimensions are net: the space necessary for mounting and maintenance has to be provided. Reduced dimensions: upon request.

BROCHURE
  • Standard Dimensions: 12′ W x 12′ H
  • Standard Operating Speed: 24 in/s
  • Operating Type: Gear driven, push-pull movement
  • Side Guide: Made of structural channels of 3 5/16″ x 2″ x 1/8″ in galvanized steel.
  • Inner Side Guide: Polyethylene (PE-UHMW 1000); outer section 1/2″ x 13/16″, fixed at the base of the structural channels with springs. This means that the door curtain is stretched between its side guides.
  • Drum: In steel, diameter 4″ x 0.078″, shafts in steel.
  • Door Curtain: Very resistant PVC (27 oz/sq.yd). Available in different colors and provided with side sealing zippers; soft bottom edge design.
  • Motor: 1/2 HP-60 Hz continuous industrial motor. (HP may vary with door size)
  • Motor Cover: Optional
BROCHURE

Dynaco the Streamline

GEARBOX
Size 50 for a motor of 1 HP and gear reduction ratio 1/28.

DOOR POSITIONING
Absolute encoder mounted onto the back of the motor.

DETECTORS
An infrared photocell installed inside the side guide and detects the presence of a pedestrian or a vehicle. Upon activation, it opens the door immediately and keeps it open as long as the presence is detected. Height of photocell: 12″ from the floor. (Optional: Up to maximum 24″ from the floor).

A bottom edge detector reverses the door when it hits an obstacle during the closing cycle. This detector is positioned at the bottom part of the curtain.

The bottom edge is referred to as a WDD or Wireless DYNACO Detector: A wireless detection system consisting of a transmitter in the bottom bag of the door and a receiver in the control box. The system operates according to the “open loop” principle: when the sensor encounters an obstacle, the transmitter leaves the standby mode and sends a signal to the receiver that immediately opens the door.

POWER SUPPLY
Standard single phase 208-230 VAC, three phase 208-230 VAC, three phase 460 VAC.

Frequency: 50-60 Hz. Circuit breakers to be provided by the customer: 10-20 A for 1 HP.

SPACE REQUIREMENTS
All indicated dimensions are net: the additional space necessary for mounting and maintenance has to be taken into account. Reduced dimensions upon request.

  • Standard Dimensions: 12′ W x 12′ H
  • Opening Speed: 48 in/s
  • Closing Speed: 24 in/s
  • Door Operation: Gravity driven with flexible soft bottom edge.
  • Side Guide: Made of structural channels of 2 1/16″ x 1 1/2″ x 1/8″ in galvanized steel.
  • Inner Side Guide: Polyethylene (PE-UHMW 1000); outer section 9/16” x 9/16”.
  • Side Guide Covers: Composite
  • Drum: In steel, diameter 4″ x 0.078″, shafts in steel.
  • Door Curtain: Reinforced PVC (27 oz/sq.yd) and continuous sealing bead, with flexible weighted soft bottom edge design. Available in different colors.
  • Vision: One vision banner 15” x door width or individual windows 24” x 24” optional.
  • Motor: Standard 1 HP at 208V, 230V or 460V. Motor is VFD driven, Nema 4, 2 poles without brake.

Albany Ultra Clean High Speed Door

CONTAIN COSTS AND CONTAMINANTS

UltraClean High Speed Doors offer fast opening and closing speeds to control air infiltration while it’s sanitary design minimizes the spread of contaminants. Two piece side column design and stainless steel components allow for easy wash down and cleaning..